SMARTGEN HAT310 120VAC ATS Controller
HAT310-120V ATS Controller is suitable for 2-stage of PC, and ATS of CC class (close signal is constant output). It can accurately detect 3-phase 4-wire mains voltage and generator single-phase voltage. When the mains under-voltage and loss of phase occurred, HAT310-120V will control ATS transfer after a delay. If the mains are unavailable, the controller has the function to initiate signals to start the gen-set.
PERFORMANCE AND CHARACTERISTICS
HAT310-120V controller can detect 3-phase 4-wire mains voltage/generator single phase voltage and control ATS.
Main characteristics are as follows,
 
- 1) With automatic charge and automatic recovery function.
 - 2) With under-voltage and loss of phase-detection function.
 - 3) LED indicators on the panel can show working status of controller clearly.
 - 4) Applicable for 2 isolated neutral line.
 - 5) Mains normal delay configured via potentiometer (range: 1~60s), and generator normal delay via potentiometer (range: 1~60s)
 - 6) Mians is unavailable, if any phase voltage belows minimum working voltage or phase loss occurred gen-set will be started.
 - 7) Output contact capacity of mains and generator transfer relay is 16A AC120V, which can directly used to drive switch conversion.
 - 8) Output contact capacity of GENS START relay is 16A AC120V, it is volt free normally-open/normally-closed contact.
 - 9) Strong anti-electromagnetic interference performance enable controller to use in the environment with strong electromagnetic interference.
 - 10) Modular design, self extinguishing ABS plastic shell, pluggable terminal, compact structure;
 - 11) Two installation ways: internal 35mm slide-way and internal screw mounting.
 
SPECIFICATION:
- Operating Voltage - AC power A1N1/A2N2 supply. Rated AC120V (range: AC90~150V)
 - Power Consumption Under rated voltage, power consumption of voltage circuit is not more than 2W
 - AC Voltage Input: - 3-phase 4-wire (120/208 VAC),
 - 2 phase 3-wire (120/240VAC),
 - single-phase 2-wire (120VAC):
 - AC70V ¨C AC150V (ph-N)
 - AC Frequency - 50/60Hz
 - Gens-set Starter Relay - 16A 120V AC Volts free output (Normally close)
 - Mains Close Relay - 16A 120V AC AC Supply output (Normally open)
 - Gen Close Relay - 16A 120V AC AC Supply output (Normally open)
 - Case Dimensions - 110mmx77.5mmx55mm
 - Screw Mounting Dimensions - 65mmx65.1mm
 - Working Conditions - Temperature: (-25~+70)¡ãC;
 - - Humidity: (20~93)%RH
 - Storage Condition - Temperature: (-25~+70)¡ãC
 - Insulation Strength - Apply AC1.5kV voltage between high voltage terminal and low voltage terminal; The leakage current is not more than 3mA within 1min.
 - Weight - 0.2kg